3T Reverse Osmosis Water Treatment Equipment
Reverse osmosis pure water equipment

3T Reverse Osmosis Water Treatment Equipment

RO membranes typically remove 90-99.9% of suspended and dissolved solids and can remove bacteria and viruses.
Model HLDRO–3000L  |  Capacity 3,000 L/H
3,000 L/HTwo-stage ROCompact skidLow running cost
Capacity3,000 L/H
Recovery50-70%
PowerAC 220V/50Hz or AC 380V/50Hz
Footprint3000 x 1080 x 2530 mm
CE-compliant build12-month warrantyOEM / ODM welcome
Product Overview

Product overview

The 3T reverse osmosis water treatment equipment is a complete reverse osmosis pure water system rated for 3 tons per hour. The whole train – pre-treatment, high-pressure pump, membrane array and control cabinet – is pre-piped and pre-wired on a single skid, so on-site work is limited to connecting the raw water inlet, the permeate outlet and the power supply. RO membranes typically remove 90-99.9% of suspended and dissolved solids and can remove bacteria and viruses, so the unit is equally at home in bottling plants, food and beverage factories, pharmaceutical and laboratory settings. Capacity, membrane arrangement and voltage are confirmed against your feed water analysis at the quotation stage.

What's included

Standard scope of supply for this configuration.

  • Feed pump and pre-treatment skid
  • Sand filter and activated carbon filter
  • Automatic softener or antiscalant dosing unit
  • 5 micron precision filter, stainless housing
  • High-pressure pump with protection switch
  • RO membrane elements in FRP vessels
  • PLC cabinet, conductivity meter, flow meters
  • SS304 frame, piping, valves and fittings
Technical Data

Specifications

Technical specifications
Equipment modelHLDRO–3000L
Water production3,000 L/H
Influent water sourceTDS up to 250 ppm, water temperature 25 C
Produced water qualityConductivity 10 us/cm or lower, TOC 0.5 mg/L or lower, microorganism 100 cfu/ml or lower
Desalination rate95-99.6%
Water recovery rate50-70%
Power supplyAC 220V/50Hz or AC 380V/50Hz
Power1.5-1.8 kW
Working pressurePre-treatment 0.2-0.4 MPa, RO host 0.8-1.5 MPa
Inlet / outlet diameterDN25 / DN20
Equipment size3000 x 1080 x 2530 mm
Equipment volume areaabout 1.5 m2
Packing volumeabout 2.35 m3
Weight230-300 KGS
ApplicationsPurified drinking water; beverage and food factories; daily chemical products factories; biopharmaceutical water; medical equipment cleaning; reagent preparation; hospital dialysis; oral liquid water; medical purified water; electronic semiconductor production water

Specifications are typical for the standard configuration and are confirmed on the approved drawing before production. Capacity, voltage and footprint can be adapted to your site.

Not the right size?

Tell us the raw water source, the hourly flow you need and the target water quality. We will confirm capacity, recovery and power before you commit.

How it works

Raw water intake

A stainless steel feed pump lifts source water from the raw water tank and holds a steady suction pressure for the whole train.

Sand and carbon filtration

A fibreglass pressure vessel with quartz sand removes turbidity; activated carbon then strips chlorine, colour and odour.

Softening or antiscalant dosing

An automatic softener, or antiscalant dosing on high-hardness sources, keeps calcium and magnesium from scaling the membranes.

Precision filtration

A 5 micron PP cartridge guard stops any residual particle before the water reaches the high-pressure section.

High-pressure RO

A multistage centrifugal pump pushes water at 0.8-1.5 MPa through the membrane elements, and permeate leaves the vessel at 10 us/cm or lower.

Storage and polish

Permeate is stored in a stainless tank and finished with UV sterilisation or ozone dosing before it is sent to filling.

Applications

Where this system is used

Selected for reverse osmosis pure water equipment duty across these sectors.
Purified drinking water
beverage and food factories
daily chemical products factories
biopharmaceutical water
medical equipment cleaning
reagent preparation
FAQ

Questions buyers ask before ordering

Start from your peak hourly demand, then add 15-20 percent headroom. If you plan to run two shifts, size on the two-shift figure so the plant is not throttled during the busiest hours.

The standard skid is designed for TDS up to 250 ppm at 25 degrees C. For brackish or high-hardness sources we adjust the pre-treatment, membrane array and pump selection at the quotation stage.

Typically two to three years when pre-treatment is maintained and the unit is flushed regularly. Membrane life drops quickly if chlorine reaches the elements, which is why the carbon filter is not optional.

Yes. 220V/50Hz, 380V/50Hz and 440V/60Hz are all available, and the control cabinet is configured to your local standard before shipment.

Standard configurations ship in 15-25 working days after the deposit and the approved drawing. Custom skids with extended pre-treatment take a little longer.

Ready to specify this system?

Send us your raw water analysis, the hourly flow you need and the target water quality. Our engineers will confirm capacity, configuration and delivery.