5T Stainless Steel RO Water Treatment Machine
Reverse osmosis pure water equipment

5T Stainless Steel RO Water Treatment Machine

RO membranes typically remove 90-99.9% of suspended and dissolved solids and can remove bacteria and viruses.
Model HLDRO–5000L  |  Capacity 5,000 L/H
5,000 L/H permeateSS304 framePLC control95-99.6% rejection
Capacity5,000 L/H
Recovery50-70%
Power1.5-1.8 kW
Footprint2800 x 580 x 1630 mm
CE-compliant build12-month warrantyOEM / ODM welcome
Product Overview

Product overview

This 5T/H unit is the workhorse of the range: a complete reverse osmosis train mounted on a single stainless steel skid, pre-piped and pre-wired so that only the raw water inlet, the permeate outlet and the power supply have to be connected on site. The frame is SS304 rather than painted carbon steel, which matters in bottling halls and food plants where wash-down is routine. Feed water passes through a fibreglass sand filter and an activated carbon filter before the softener and the 5 micron guard. That sequence is deliberate: the carbon protects the membranes from chlorine, and the softener protects them from hardness, so the elements keep their rejection rate instead of scaling within the first season. The high-pressure section uses a multistage centrifugal pump with low-pressure and high-pressure protection. Permeate conductivity is displayed continuously on the PLC, and the machine alarms on out-of-spec water rather than quietly sending it to the filling line.

What's included

Standard scope of supply for this configuration.

  • Feed pump and pre-treatment skid
  • Sand filter and activated carbon filter
  • Automatic softener or antiscalant dosing unit
  • 5 micron precision filter, stainless housing
  • High-pressure pump with protection switch
  • RO membrane elements in FRP vessels
  • PLC cabinet, conductivity meter, flow meters
  • SS304 frame, piping, valves and fittings
Technical Data

Specifications

Technical specifications
Equipment modelHLDRO–5000L
Water production5,000 L/H
Influent water sourceTDS up to 250 ppm, water temperature 25 C
Produced water qualityConductivity 10 us/cm or lower, TOC 0.5 mg/L or lower, microorganism 100 cfu/ml or lower
Desalination rate95-99.6%
Water recovery rate50-70%
Power supplyAC 220V/50Hz or AC 380V/50Hz
Power1.5-1.8 kW
Working pressurePre-treatment 0.2-0.4 MPa, RO host 0.8-1.5 MPa
Inlet / outlet diameterDN25 / DN20
Equipment size2800 x 580 x 1630 mm
Packing volumeabout 2.35 m3
Weight230-500 kg
ApplicationsPurified drinking water, beverage and food production, chemical and biopharmaceutical water, medical equipment cleaning, reagent preparation, dialysis water, electronic production water

Specifications are typical for the standard configuration and are confirmed on the approved drawing before production. Capacity, voltage and footprint can be adapted to your site.

Not the right size?

Tell us the raw water source, the hourly flow you need and the target water quality. We will confirm capacity, recovery and power before you commit.

How it works

From raw water to finished water

Raw water intake

A stainless steel feed pump lifts source water from the raw water tank and holds a steady suction pressure for the whole train.

Sand and carbon filtration

A fibreglass pressure vessel with quartz sand removes turbidity; activated carbon then strips chlorine, colour and odour.

Softening or antiscalant dosing

An automatic softener, or antiscalant dosing on high-hardness sources, keeps calcium and magnesium from scaling the membranes.

Precision filtration

A 5 micron PP cartridge guard stops any residual particle before the water reaches the high-pressure section.

High-pressure RO

A multistage centrifugal pump pushes water at 0.8-1.5 MPa through the membrane elements, and permeate leaves the vessel at 10 us/cm or lower.

Storage and polish

Permeate is stored in a stainless tank and finished with UV sterilisation or ozone dosing before it is sent to filling.

Applications

Where this system is used

Selected for reverse osmosis pure water equipment duty across these sectors.
Drinking water plants
Beverage and food factories
Pharmaceutical and biotech
Chemical production
Hospitals and dialysis
Electronics manufacturing
FAQ

Questions buyers ask before ordering

Start from your peak hourly demand, then add 15-20 percent headroom. If you plan to run two shifts, size on the two-shift figure so the plant is not throttled during the busiest hours.

The standard skid is designed for TDS up to 250 ppm at 25 degrees C. For brackish or high-hardness sources we adjust the pre-treatment, membrane array and pump selection at the quotation stage.

Typically two to three years when pre-treatment is maintained and the unit is flushed regularly. Membrane life drops quickly if chlorine reaches the elements, which is why the carbon filter is not optional.

Yes. 220V/50Hz, 380V/50Hz and 440V/60Hz are all available, and the control cabinet is configured to your local standard before shipment.

Standard configurations ship in 15-25 working days after the deposit and the approved drawing. Custom skids with extended pre-treatment take a little longer.

Ready to specify this system?

Send us your raw water analysis, the hourly flow you need and the target water quality. Our engineers will confirm capacity, configuration and delivery.