Standard scope of supply for this configuration.
| Technical specifications | |
|---|---|
| Model | FSHB1.5 / FSHB3 / FSHB5 / FSHB10 / FSHB20 / FSHB30 |
| Water production (m³) | 1.5 / 3 / 5 / 10 / 20 / 30 |
| Desalination rate | 99.20% |
| Salt content of product water | ≤700 |
| Operating pressure (MPa) | 3.5-5.5 |
| Equipment size (cm) | 50*57*135 / 50*57*135 / 91*50*154 / 170*112*190 / 170*112*190 / 244*100*212 |
| Use power (KW) | 1.5 / 1.5 / 2.2 / 5.5 / 5.5 / 15 |
| Weight (KG) | 120 / 150 / 400 / 600 / 800 / 1200 |
Specifications are typical for the standard configuration and are confirmed on the approved drawing before production. Capacity, voltage and footprint can be adapted to your site.
Tell us the raw water source, the hourly flow you need and the target water quality. We will confirm capacity, recovery and power before you commit.
A booster pump feeds the pressure vessel at a steady flow so the resin bed is loaded evenly.
Strong-acid cation resin exchanges calcium and magnesium for sodium, removing hardness down to 0.03 mmol/L.
Treated water flows to the boiler, laundry or process line while the controller counts the treated volume.
At the set point the controller draws saturated brine from the salt box and regenerates the resin.
Brine is displaced and the bed is rinsed to specification before the unit returns to service.
Duty and standby vessels alternate automatically, so softened water is available without interruption.
From peak flow in m3/h and total hardness in mmol/L. That gives the resin volume and the interval between regenerations, which is what actually decides the tank size.
Roughly 3-5 kg of salt per cubic metre of resin per regeneration, depending on the hardness and the efficiency setting you choose.
Yes. Softening exchanges calcium and magnesium for a small amount of sodium. Where sodium intake is a concern, use a separate unsoftened drinking water tap.
Duty and standby tanks alternate automatically, so softened water is available during regeneration. Single-tank units pause for 60-90 minutes per cycle.
Topping up the salt, checking the injector and brine line, and an annual resin inspection. The controller logs regeneration cycles for you.

The use of softened water equipment can remove the content of calcium and magnesium ions in the water and reduce the cal…

Mainly used in steam boiler soft water, domestic water and soft water treatment in food, chemical, pharmaceutical and ot…

It is suitable for the softening of make-up water for steam boiler soft water, hot water boilers, exchangers, evaporativ…