Chip Production Equipment for Ultrapure Water
EDI ultrapure water equipment

Chip Production Equipment for Ultrapure Water

Built-in ultra-pure water circulation program to ensure the purity of the water quality, install precision disinfection equipment, effectively control the growth of bacteria, and ensure that the quality of the output water fully meets the use standards.
Model HLDEDI—500L  |  Capacity 500 L/H
500 L/HRO + EDINo chemical regenerationCompact footprint
Capacity500 L/H
Product waterConductivity <10 μs/cm
PowerAC220V/50Hz or AC380V/50Hz
Footprint1500*580*1600
CE-compliant build12-month warrantyOEM / ODM welcome
Product Overview

Product overview

The Chip production equipment for ultrapure water is an EDI ultrapure water system rated for the capacity stated on the datasheet. Electrodeionisation polishes RO permeate to laboratory-grade resistivity without the chemical regeneration that mixed-bed resins require, so the skid runs continuously with only routine monitoring. Because no acid and caustic are handled on site, the unit suits pharmaceutical and biotech plants, hospital dialysis centres, electronics and semiconductor lines and any facility where chemical storage is restricted. Resistivity, flow and pressure are displayed on the control panel and alarms stop the system on out-of-spec water.

What's included

Standard scope of supply for this configuration.

  • Pre-treatment vessels and precision filter
  • Two-stage RO array with high-pressure pump
  • RO permeate storage tank
  • EDI stack and power supply module
  • Polishing loop with 0.22 micron filter
  • Inline resistivity and flow instrumentation
  • PLC cabinet with data logging
  • SS304 skid, piping and valves
Technical Data

Specifications

Technical specifications
Equipment modelHLDEDI—500L
Water production500 L/H
Influential water sourceTDS ≤260 PPM, water temperature 25 ℃
Produced water qualityConductivity <10 μs/cm
Desalination rate98-99.9%
Water recovery rate50-70%
Power supplyAC220V/50Hz or AC380V/50Hz
Power1.5-2 KW
Work pressurePretreatment 0.2-0.4 MPa, RO host 0.8-1.5 MPa
Inlet diameter (mm)DN25-32
Outlet diameter (mm)DN20
Equipment size (mm)1500*580*1600
Equipment volume areaabout 1.5 m²
Packing volumeabout 0.35 m³
Weight (KGS)230-500 KGS
ApplicationsPurified drinking water, purified water used in beverage and food factories; production water in daily chemical products factories, biopharmaceutical water, medical equipment cleaning water, reagent preparation water, hospital dialysis water, oral liquid water, medical purified water, electronic semiconductor production water

Specifications are typical for the standard configuration and are confirmed on the approved drawing before production. Capacity, voltage and footprint can be adapted to your site.

Not the right size?

Tell us the raw water source, the hourly flow you need and the target water quality. We will confirm capacity, recovery and power before you commit.

How it works

Pre-treatment

Sand, carbon and softener vessels condition the feed water so the RO and EDI stacks see a stable, low-fouling stream.

Reverse osmosis

A two-stage RO array removes the bulk of dissolved solids and brings conductivity down to the single-digit us/cm range.

RO permeate tank

Treated water is buffered in a stainless tank, which decouples RO output from the EDI demand.

EDI stack

An electrical field drives ions through ion-exchange membranes, so no acid or caustic regeneration is needed.

Ultrapure loop

Polishing and 0.22 micron filtration deliver water at 10-18.2 MOhm.cm to the point of use.

Monitoring

Inline resistivity, flow and pressure transmitters report to the PLC and log every batch.

Applications

Where this system is used

Selected for edi ultrapure water equipment duty across these sectors.
Purified drinking water, purified water used in beverage and food factories
production water in daily chemical products factories, biopharmaceutical water, medical equipment cleaning water, reagent preparation water, hospital dialysis water, oral liquid water, medical purified water, electronic semiconductor production water
FAQ

Questions buyers ask before ordering

Yes. EDI needs a low-conductivity feed, so RO is always part of the train. The EDI stack then polishes the permeate to ultrapure quality without chemical regeneration.

EDI runs continuously and regenerates electrically in place, so there is no acid or caustic handling, no resin replacement shut-down and no chemical waste stream.

Resistivity of 10-18.2 MOhm.cm depending on the feed and the polishing loop, with TOC below 0.5 mg/L and microbial counts under 100 cfu/ml.

Annual inspection of the stacks, seals and electrodes, plus continuous monitoring of differential pressure and resistivity. Consumables are limited to cartridge filters and UV lamps.

The PLC handles start-up, standby, alarm and data logging, so the plant can run with a daily operator round rather than full-time attendance.

Ready to specify this system?

Send us your raw water analysis, the hourly flow you need and the target water quality. Our engineers will confirm capacity, configuration and delivery.